York Mini-Split Error Codes: Troubleshooting Guide

York mini-splits display fault codes as alphanumeric codes on the indoor unit's LED display. York's ductless lineup is built on a platform shared with their parent company Johnson Controls' portfolio — error codes are consistent across the York ductless range and broadly follow industry-standard designations. This guide covers the most common York error codes and recommended first responses.

Klima - Smart Home Thermostat for Mini-splits, Air Conditioners and Heatpumps

Compatible with all brands of ACs and Mini-Splits Automate Climate Management Control remotely Reduce Energy Consumption Monitor bills in realtime

Try Now
Product Image

Common York Mini-Split Error Codes

Error Code Meaning DIY Fix? First Step
E1 High pressure protection Partially Clear outdoor unit airflow; reset at breaker
E2 Low pressure / refrigerant issue No Call EPA-certified technician — refrigerant leak check
E3 Outdoor fan motor fault Partially Check for debris around outdoor unit; call tech
E4 Compressor overload Partially Clear outdoor unit; reset; call tech if recurring
E5 Overcurrent protection No Reset breaker; verify electrical supply; call tech
E6 Communication error (indoor to outdoor) Partially Reset at breaker; check signal wire at both units
F1 Indoor intake temperature sensor fault No Reset; call tech if recurring — thermistor
F2 Indoor coil temperature sensor fault No Call technician — thermistor replacement
P1 Freeze protection — coil too cold Yes Clean filter; let coil thaw 2–3 hrs; restart
P2 Drain fault / condensate blockage Yes Clear the condensate drain line

Frequently Asked Questions

My York mini-split shows E6 after a power outage — why?

Power outages can disrupt the communication handshake between the indoor and outdoor units, producing an E6 fault at startup. A full breaker reset (off 30 seconds, on, wait 3 minutes) resolves post-outage E6 in the majority of cases. If E6 returns consistently after the reset, inspect the signal wire connections at both the indoor and outdoor unit terminal blocks for loose or damaged wiring.

Where can I find York's complete error code list?

York's full error code documentation is in the service manual for your specific model, downloadable from York's technical literature portal using the model number from the unit's nameplate. York's dealer service team can also provide model-specific diagnostic support.

Related reading:
Mini-Split Error Codes: Complete Guide by Brand
How to Reset a Mini-Split: Step-by-Step for Every Brand
York Mini-Split Review 2026: Should You Buy It?

York Mini-Split Error Codes: Troubleshooting Guide

Klima - Smart Home Controller for Mini-splits, Air Conditioners and Heatpumps

Compatible with all brands of ACs and Mini-Splits Automate Climate Management   Control remotely   Reduce Energy Consumption   Monitor bills in realtime

Try Now

Recent Articles

Bryant Mini-Split Review 2026: Full Performance Analysis
Bryant Mini-Split Review 2026: Full Performance Analysis

Bryant is a Carrier subsidiary brand — their ductless mini-split sy...

Read More
Mini-Split for Server Room: Keeping Equipment Cool
Mini-Split for Server Room: Keeping Equipment Cool

A server room or IT closet has unique climate control requirements ...

Read More
Mini-Split Cold Climate Performance: How Low Can They Go?
Mini-Split Cold Climate Performance: How Low Can They Go?

Understanding exactly how far a mini-split can heat in cold weather...

Read More
Mini-Split Balance Point Temperature: What It Is
Mini-Split Balance Point Temperature: What It Is

The balance point temperature is the outdoor temperature at which a...

Read More
Mini-Split Heat Pump COP: What It Means and Why It Matters
Mini-Split Heat Pump COP: What It Means and Why It Matters

COP (Coefficient of Performance) is the fundamental efficiency metr...

Read More